ControlForge Omron FINS Protocol Guide

James M. Belcher Founder, JMB Technical Services LLC April 2026 | ControlForge v1.0.533


1. Architecture Overview

ControlForge implements an Omron FINS (Factory Interface Network Service) client — callable directly from IEC 61131-3 Structured Text. No external libraries, no configuration files, no code generation. You create connections, read/write PLC memory areas, configure background polling, and manage clients with plain function calls in your ST programs.

RoleFunctionsUse Case
ClientFINS_CLIENT_CREATE / FINS_CLIENT_READ_* / FINS_CLIENT_WRITE_* / FINS_CLIENT_ADD_*_POLLRead/write memory areas on Omron CJ, NJ, NX series PLCs

This is a client-only protocol in ControlForge. The FINS client connects to Omron PLCs over UDP (default port 9600) using the FINS/UDP transport, reading and writing the PLC's Data Memory (DM), Core I/O (CIO), and other memory areas.

System Diagram

Omron Memory Areas

Omron PLCs organize data into named memory areas. ControlForge's FINS client provides direct access to the two most commonly used areas:

AreaFINS CodeAddress RangeDescription
DM (Data Memory)0x82D0 - D32767General-purpose storage. Recipes, setpoints, configuration parameters. Retentive by default on most CPUs.
CIO (Core I/O)0xB0CIO 0 - CIO 6143Physical I/O image, internal relays, and inter-unit communication. Bits map directly to I/O terminals.

Addressing Note: ControlForge uses zero-based word addressing. Address 0 reads D0 (or CIO 0). A count of 10 reads 10 consecutive 16-bit words. This matches CX-Programmer and Sysmac Studio conventions.

FINS Node Addressing

FINS uses a source/destination node model to route messages across Omron networks. Every FINS frame carries a destination node address (the PLC) and a source node address (ControlForge).

ParameterDescriptionTypical Value
destNodePLC's FINS node address — usually the last octet of its IP address34 (for 10.0.0.34)
srcNodeControlForge's FINS node address — usually the last octet of its IP address196 (for 10.0.0.196)

Auto-addressing: On Ethernet, Omron PLCs typically derive the FINS node address from the last octet of the IP address. If the PLC is at 10.0.0.34, its node address is 34. Set destNode accordingly. If you leave the node addresses at their defaults (0), the FINS/UDP automatic node negotiation will resolve them during the initial handshake — but explicit addressing is more reliable and avoids the negotiation round-trip.


2. Client Functions

The FINS client connects to an Omron PLC over UDP and performs read/write operations on PLC memory areas. It also supports background polling to keep local copies of memory ranges current.

2.1 Connection Management

FINS_CLIENT_CREATE — Create Named Connection

FINS_CLIENT_CREATE(name: STRING, host: STRING [, port: INT] [, destNode: INT]
[, srcNode: INT] [, pollRateMs: INT]) : BOOL
ParamTypeRequiredDefaultDescription
nameSTRINGYesUnique connection name
hostSTRINGYesIP address or hostname of the Omron PLC
portINTNo9600FINS/UDP port
destNodeINTNo0PLC's FINS node address (0 = auto-negotiate)
srcNodeINTNo0ControlForge's FINS node address (0 = auto-negotiate)
pollRateMsINTNo100Background poll interval in milliseconds

Returns: BOOL — TRUE if the client was created successfully.

(* Minimal — auto-negotiate nodes, default port and poll rate *)
ok := FINS_CLIENT_CREATE('omron1', '10.0.0.34');

(* Explicit node addressing — recommended for production *)
ok := FINS_CLIENT_CREATE('omron1', '10.0.0.34', 9600, 34, 196);

(* Explicit everything — 50ms poll rate for fast I/O *)
ok := FINS_CLIENT_CREATE('omron1', '10.0.0.34', 9600, 34, 196, 50);

Named connections: Every FINS client connection has a unique string name. This name is used in all subsequent calls. You can create as many connections as you need — one per PLC is the typical pattern.

FINS_CLIENT_CONNECT — Open UDP Connection

ParamTypeDescription
nameSTRINGConnection name from FINS_CLIENT_CREATE

Returns: BOOL — TRUE if connected successfully.

ok := FINS_CLIENT_CONNECT('omron1');

UDP connection: Unlike TCP-based protocols, FINS uses UDP. "Connecting" establishes the local socket, performs FINS node address negotiation (if nodes are set to 0), and starts the background poll loop if any poll items have been registered.

FINS_CLIENT_DISCONNECT — Close Connection

ParamTypeDescription
nameSTRINGConnection name

Returns: BOOL — TRUE if disconnected successfully.

ok := FINS_CLIENT_DISCONNECT('omron1');

FINS_CLIENT_IS_CONNECTED — Check Connection State

ParamTypeDescription
nameSTRINGConnection name

Returns: BOOL — TRUE if the connection is active.

IF NOT FINS_CLIENT_IS_CONNECTED('omron1') THEN
FINS_CLIENT_CONNECT('omron1');
END_IF;

FINS_CLIENT_DELETE — Remove Client

ParamTypeDescription
nameSTRINGConnection name

Returns: BOOL — TRUE if the client was removed.

Disconnects (if connected) and removes the client instance, including all poll items.

ok := FINS_CLIENT_DELETE('omron1');

FINS_CLIENT_LIST — List All Clients

Returns: []STRING — Array of client instance names.

clients := FINS_CLIENT_LIST();
(* Returns: ['omron1', 'omron2'] *)

Example: Connection Lifecycle

PROGRAM POU_FINSInit
VAR
state : INT := 0;
ok : BOOL;
END_VAR

CASE state OF
0: (* Create connection with explicit node addresses *)
ok := FINS_CLIENT_CREATE('omron1', '10.0.0.34', 9600, 34, 196, 100);
IF ok THEN
state := 1;
END_IF;

1: (* Register poll items before connecting *)
FINS_CLIENT_ADD_DM_POLL('omron1', 0, 100); (* D0-D99 *)
FINS_CLIENT_ADD_CIO_POLL('omron1', 0, 32); (* CIO 0-31 *)
state := 2;

2: (* Connect — starts polling *)
ok := FINS_CLIENT_CONNECT('omron1');
IF ok THEN
state := 10;
END_IF;

10: (* Running — read/write in other programs *)
IF NOT FINS_CLIENT_IS_CONNECTED('omron1') THEN
state := 2; (* Reconnect *)
END_IF;
END_CASE;
END_PROGRAM

2.2 Reading Memory Areas

FINS_CLIENT_READ_DM — Read Data Memory (Multiple Words)

ParamTypeDescription
nameSTRINGConnection name
addressINTStarting DM address (0-based)
countINTNumber of 16-bit words to read

Returns: []INT — Array of 16-bit word values.

(* Read 10 words starting at D0 *)
dm_vals := FINS_CLIENT_READ_DM('omron1', 0, 10);
(* dm_vals[0] = D0, dm_vals[1] = D1, ..., dm_vals[9] = D9 *)

(* Read recipe parameters at D1000-D1019 *)
recipe := FINS_CLIENT_READ_DM('omron1', 1000, 20);

FINS_CLIENT_READ_DM_WORD — Read Single DM Word

ParamTypeDescription
nameSTRINGConnection name
addressINTDM address (0-based)

Returns: INT — Single 16-bit word value.

(* Read setpoint from D100 *)
setpoint := FINS_CLIENT_READ_DM_WORD('omron1', 100);

When to use which: Use FINS_CLIENT_READ_DM_WORD for reading a single register (e.g., a setpoint or status word). Use FINS_CLIENT_READ_DM when you need a contiguous block (e.g., recipe data, array values). Reading a block in one call is significantly more efficient than reading words individually in a loop.

FINS_CLIENT_READ_CIO — Read Core I/O Area (Multiple Words)

ParamTypeDescription
nameSTRINGConnection name
addressINTStarting CIO address (0-based)
countINTNumber of 16-bit words to read

Returns: []INT — Array of 16-bit word values.

(* Read 16 words of I/O image starting at CIO 0 *)
io_image := FINS_CLIENT_READ_CIO('omron1', 0, 16);

(* Check bit 3 of CIO word 0 — physical input terminal 0.03 *)
input_03 := (io_image[0] AND 16#0008) <> 0;

FINS_CLIENT_READ_CIO_WORD — Read Single CIO Word

ParamTypeDescription
nameSTRINGConnection name
addressINTCIO address (0-based)

Returns: INT — Single 16-bit word value.

(* Read CIO word 100 — internal relay area *)
relay_word := FINS_CLIENT_READ_CIO_WORD('omron1', 100);

Example: Reading Mixed Areas

PROGRAM POU_FINSRead
VAR
setpoint : INT;
actual_temp : INT;
io_status : INT;
input_bit_5 : BOOL;
dm_block : ARRAY[0..9] OF INT;
i : INT;
END_VAR

IF FINS_CLIENT_IS_CONNECTED('omron1') THEN
(* Read individual values *)
setpoint := FINS_CLIENT_READ_DM_WORD('omron1', 100);
actual_temp := FINS_CLIENT_READ_DM_WORD('omron1', 101);

(* Read I/O status word *)
io_status := FINS_CLIENT_READ_CIO_WORD('omron1', 0);
input_bit_5 := (io_status AND 16#0020) <> 0;

(* Read a block of DM registers *)
dm_block := FINS_CLIENT_READ_DM('omron1', 200, 10);
END_IF;
END_PROGRAM

2.3 Writing Memory Areas

FINS_CLIENT_WRITE_DM — Write Data Memory (Multiple Words)

ParamTypeDescription
nameSTRINGConnection name
addressINTStarting DM address (0-based)
values[]INTArray of 16-bit word values to write

Returns: BOOL — TRUE if the write was acknowledged by the PLC.

(* Write 5 recipe values starting at D500 *)
ok := FINS_CLIENT_WRITE_DM('omron1', 500, [1000, 2000, 500, 100, 50]);

(* Zero out a range *)
ok := FINS_CLIENT_WRITE_DM('omron1', 600, [0, 0, 0, 0, 0, 0, 0, 0, 0, 0]);

FINS_CLIENT_WRITE_DM_WORD — Write Single DM Word

ParamTypeDescription
nameSTRINGConnection name
addressINTDM address (0-based)
valueINT16-bit word value to write

Returns: BOOL — TRUE if the write was acknowledged by the PLC.

(* Write setpoint to D100 *)
ok := FINS_CLIENT_WRITE_DM_WORD('omron1', 100, 1500);

(* Set command word *)
ok := FINS_CLIENT_WRITE_DM_WORD('omron1', 200, 16#0001);

Example: Read-Modify-Write Pattern

PROGRAM POU_FINSWrite
VAR
state : INT := 0;
ok : BOOL;
current_val : INT;
new_setpoint : INT := 2500;
END_VAR

IF FINS_CLIENT_IS_CONNECTED('omron1') THEN
CASE state OF
0: (* Write a new setpoint to the PLC *)
ok := FINS_CLIENT_WRITE_DM_WORD('omron1', 100, new_setpoint);
IF ok THEN
state := 1;
END_IF;

1: (* Verify the write by reading back *)
current_val := FINS_CLIENT_READ_DM_WORD('omron1', 100);
IF current_val = new_setpoint THEN
state := 10; (* Success *)
ELSE
state := 0; (* Retry *)
END_IF;

10: (* Done — normal operation *)
(* ... *)
END_CASE;
END_IF;
END_PROGRAM

2.4 Background Polling

The FINS client supports automatic background polling of memory ranges. Registered poll items are read at the configured pollRateMs interval, keeping a local cache current. On-demand FINS_CLIENT_READ_DM / FINS_CLIENT_READ_CIO calls return cached values when the requested range falls within a polled region, avoiding redundant network traffic.

Poll cycle (every pollRateMs):
For each registered poll item:
Build FINS Memory Area Read frame

UDP to PLC (port 9600)

PLC responds with word data

ControlForge updates local cache

ST code reads latest values (from cache, zero-latency)

FINS_CLIENT_ADD_POLL_ITEM — Add Generic Poll Item

ParamTypeDescription
nameSTRINGConnection name
areaSTRINGMemory area identifier: 'DM' or 'CIO'
addressINTStarting address
countINTNumber of 16-bit words to poll

Returns: BOOL — TRUE if the poll item was registered.

(* Poll D0-D99 every cycle *)
ok := FINS_CLIENT_ADD_POLL_ITEM('omron1', 'DM', 0, 100);

(* Poll CIO 0-31 every cycle *)
ok := FINS_CLIENT_ADD_POLL_ITEM('omron1', 'CIO', 0, 32);

FINS_CLIENT_ADD_DM_POLL — Convenience DM Poll

ParamTypeDescription
nameSTRINGConnection name
addressINTStarting DM address
countINTNumber of DM words to poll

Returns: BOOL — TRUE if the poll item was registered.

Equivalent to FINS_CLIENT_ADD_POLL_ITEM(name, 'DM', address, count).

(* Poll D0-D99 *)
ok := FINS_CLIENT_ADD_DM_POLL('omron1', 0, 100);

(* Poll recipe area D1000-D1099 *)
ok := FINS_CLIENT_ADD_DM_POLL('omron1', 1000, 100);

FINS_CLIENT_ADD_CIO_POLL — Convenience CIO Poll

ParamTypeDescription
nameSTRINGConnection name
addressINTStarting CIO address
countINTNumber of CIO words to poll

Returns: BOOL — TRUE if the poll item was registered.

Equivalent to FINS_CLIENT_ADD_POLL_ITEM(name, 'CIO', address, count).

(* Poll CIO 0-31 — physical I/O image *)
ok := FINS_CLIENT_ADD_CIO_POLL('omron1', 0, 32);

Register poll items before connecting. Add all your poll items after FINS_CLIENT_CREATE but before FINS_CLIENT_CONNECT. The poll loop starts when the connection is established. You can add poll items after connecting, but they take effect on the next poll cycle.

Max payload: A single FINS Memory Area Read response can carry up to 999 words (1998 bytes). If your poll count exceeds 999, ControlForge splits it into multiple FINS requests automatically. For best performance, keep individual poll ranges under 999 words.

Example: Polled Data with On-Demand Reads

PROGRAM POU_FINSPolling
VAR
state : INT := 0;
ok : BOOL;
dm_block : ARRAY[0..9] OF INT;
setpoint : INT;
io_word : INT;
motor_running : BOOL;
END_VAR

CASE state OF
0: (* Create and configure *)
ok := FINS_CLIENT_CREATE('omron1', '10.0.0.34', 9600, 34, 196, 100);
IF ok THEN
(* Register poll ranges *)
FINS_CLIENT_ADD_DM_POLL('omron1', 0, 200); (* D0-D199 polled *)
FINS_CLIENT_ADD_CIO_POLL('omron1', 0, 32); (* CIO 0-31 polled *)
state := 1;
END_IF;

1: (* Connect — polling starts *)
ok := FINS_CLIENT_CONNECT('omron1');
IF ok THEN
state := 10;
END_IF;

10: (* Normal operation — reads come from cache *)
IF FINS_CLIENT_IS_CONNECTED('omron1') THEN
(* These reads are served from the poll cache *)
dm_block := FINS_CLIENT_READ_DM('omron1', 0, 10);
setpoint := FINS_CLIENT_READ_DM_WORD('omron1', 100);

(* CIO reads also from cache *)
io_word := FINS_CLIENT_READ_CIO_WORD('omron1', 0);
motor_running := (io_word AND 16#0001) <> 0;
ELSE
state := 1; (* Reconnect *)
END_IF;
END_CASE;
END_PROGRAM

3. Supported PLC Series

ControlForge's FINS client is compatible with any Omron PLC that supports FINS/UDP. This includes the following series:

SeriesModelsNotes
CJ1CJ1M, CJ1H, CJ1GOlder series. FINS over Ethernet via ETN21 unit.
CJ2CJ2M, CJ2HBuilt-in Ethernet on CPU. Most common in brownfield installations.
NJNJ101, NJ301, NJ501Sysmac series. FINS supported alongside EtherNet/IP.
NXNX1P2, NX102, NX502, NX701Latest generation. FINS supported by default. Enable in Sysmac Studio under PLC > Built-in EtherNet/IP Port Settings > FINS.
CPCP1L, CP1H, CP1ECompact PLCs. FINS via optional Ethernet adapter (CP1W-CIF41).
CSCS1G, CS1H, CS1DLegacy rack PLCs. FINS over Ethernet via ETN21 unit.

NX/NJ Series: On Sysmac controllers, FINS is disabled by default. In Sysmac Studio, navigate to Controller Setup > Built-in EtherNet/IP Port > FINS Settings and set FINS/UDP: Enable. Also confirm the FINS node address matches the last octet of the IP or set it explicitly.


4. FINS Protocol Notes

4.1 Transport

FINS/UDP uses port 9600 by default. ControlForge sends FINS commands as UDP datagrams. Each request/response is a single UDP packet containing a FINS header and command payload.

┌──────────────────────────────────────────┐
│ UDP Datagram (Port 9600) │
│ │
│ ┌────────────────────────────────────┐ │
│ │ FINS Header (10 bytes) │ │
│ │ │ │
│ │ ICF RSV GCT DNA DA1 DA2 │ │
│ │ SNA SA1 SA2 SID │ │
│ ├────────────────────────────────────┤ │
│ │ FINS Command (2 bytes) │ │
│ │ │ │
│ │ MRC SRC │ │
│ ├────────────────────────────────────┤ │
│ │ Command Data (variable) │ │
│ │ │ │
│ │ Area code, start address, count │ │
│ └────────────────────────────────────┘ │
└──────────────────────────────────────────┘
FieldSizeDescription
ICF1 byteInformation Control Field (0x80 = command, 0xC0 = response)
RSV1 byteReserved (0x00)
GCT1 byteGateway Count (0x02 default)
DNA1 byteDestination Network Address (0x00 = local)
DA11 byteDestination Node Address (destNode)
DA21 byteDestination Unit Address (0x00 = CPU unit)
SNA1 byteSource Network Address (0x00 = local)
SA11 byteSource Node Address (srcNode)
SA21 byteSource Unit Address (0x00)
SID1 byteService ID (sequence number, 0x00-0xFF)

You never build FINS frames manually — FINS_CLIENT_READ_DM, FINS_CLIENT_WRITE_DM, and the other functions handle all framing, sequencing, and error checking.

4.2 FINS Commands Used

OperationMRCSRCDescription
Memory Area Read0101Read words from DM, CIO, WR, HR, AR
Memory Area Write0102Write words to DM, CIO, WR, HR, AR

4.3 Error Handling

FINS responses include a 2-byte end code. ControlForge interprets these and surfaces them as function return values:

End CodeMeaningControlForge Behavior
0x0000Normal completionFunction returns requested data
0x0001Service canceledRetry on next poll cycle
0x0105Node address out of rangeCheck destNode/srcNode settings
0x0204Address out of rangeCheck DM/CIO address bounds
0x0401Aborted due to unit errorPLC CPU error — check PLC status

Read functions return zero values on error. Write functions return FALSE. Check FINS_CLIENT_IS_CONNECTED to distinguish between a communication failure and a PLC-side error.

4.4 Timing

ParameterTypical ValueNotes
UDP round-trip1-5 msLocal network, switched Ethernet
Poll cycle (default)100 msConfigurable via pollRateMs
FINS response timeout2 secondsControlForge internal timeout before marking connection lost
Reconnect backoff1-10 secondsExponential backoff on repeated failures

5. Practical Examples

5.1 Temperature Monitoring (CJ2M)

A CJ2M PLC reads thermocouples via an analog input unit. Temperature values (scaled to 0.1 degC) are stored in D100-D103. ControlForge polls these values and exposes them to other systems.

PROGRAM POU_TempMonitor
VAR
state : INT := 0;
ok : BOOL;
temps : ARRAY[0..3] OF INT;
zone1_degC : REAL;
zone2_degC : REAL;
zone3_degC : REAL;
zone4_degC : REAL;
alarm : BOOL;
HIGH_LIMIT : REAL := 85.0;
END_VAR

CASE state OF
0: (* Initialize *)
ok := FINS_CLIENT_CREATE('cj2m', '10.0.0.34', 9600, 34, 196, 100);
IF ok THEN
FINS_CLIENT_ADD_DM_POLL('cj2m', 100, 4); (* D100-D103 *)
state := 1;
END_IF;

1: (* Connect *)
ok := FINS_CLIENT_CONNECT('cj2m');
IF ok THEN
state := 10;
END_IF;

10: (* Running *)
IF FINS_CLIENT_IS_CONNECTED('cj2m') THEN
temps := FINS_CLIENT_READ_DM('cj2m', 100, 4);

(* Scale from 0.1 degC to degC *)
zone1_degC := INT_TO_REAL(temps[0]) / 10.0;
zone2_degC := INT_TO_REAL(temps[1]) / 10.0;
zone3_degC := INT_TO_REAL(temps[2]) / 10.0;
zone4_degC := INT_TO_REAL(temps[3]) / 10.0;

(* High temperature alarm *)
alarm := (zone1_degC > HIGH_LIMIT) OR
(zone2_degC > HIGH_LIMIT) OR
(zone3_degC > HIGH_LIMIT) OR
(zone4_degC > HIGH_LIMIT);
ELSE
state := 1; (* Reconnect *)
END_IF;
END_CASE;
END_PROGRAM

5.2 Motor Control via CIO Bits

Read physical I/O status from CIO and write command words to DM registers used by the PLC's motor control logic.

PROGRAM POU_MotorControl
VAR
state : INT := 0;
ok : BOOL;
io_word : INT;
start_button : BOOL;
stop_button : BOOL;
motor_feedback : BOOL;
cmd_run : INT := 0;
END_VAR

CASE state OF
0: (* Initialize *)
ok := FINS_CLIENT_CREATE('line1', '10.0.0.34', 9600, 34, 196, 50);
IF ok THEN
FINS_CLIENT_ADD_CIO_POLL('line1', 0, 4); (* CIO 0-3: input terminals *)
FINS_CLIENT_ADD_DM_POLL('line1', 200, 10); (* D200-D209: status area *)
state := 1;
END_IF;

1: (* Connect *)
ok := FINS_CLIENT_CONNECT('line1');
IF ok THEN
state := 10;
END_IF;

10: (* Running *)
IF FINS_CLIENT_IS_CONNECTED('line1') THEN
(* Read physical inputs from CIO *)
io_word := FINS_CLIENT_READ_CIO_WORD('line1', 0);
start_button := (io_word AND 16#0001) <> 0; (* CIO 0.00 *)
stop_button := (io_word AND 16#0002) <> 0; (* CIO 0.01 *)
motor_feedback := (io_word AND 16#0004) <> 0; (* CIO 0.02 *)

(* Motor control logic *)
IF start_button AND NOT stop_button THEN
cmd_run := 1;
ELSIF stop_button THEN
cmd_run := 0;
END_IF;

(* Write command to PLC *)
FINS_CLIENT_WRITE_DM_WORD('line1', 300, cmd_run);
ELSE
state := 1;
END_IF;
END_CASE;
END_PROGRAM

5.3 Multi-PLC Communication

ControlForge can communicate with multiple Omron PLCs simultaneously. Each gets its own named connection.

PROGRAM POU_MultiPLC
VAR
state : INT := 0;
ok : BOOL;
mixer_speed : INT;
conveyor_status : INT;
fill_level : INT;
END_VAR

CASE state OF
0: (* Create connections to three PLCs *)
ok := FINS_CLIENT_CREATE('mixer', '10.0.0.34', 9600, 34, 196, 100);
ok := FINS_CLIENT_CREATE('conveyor', '10.0.0.35', 9600, 35, 196, 100);
ok := FINS_CLIENT_CREATE('filler', '10.0.0.36', 9600, 36, 196, 100);

(* Register polls *)
FINS_CLIENT_ADD_DM_POLL('mixer', 0, 50);
FINS_CLIENT_ADD_DM_POLL('conveyor', 0, 50);
FINS_CLIENT_ADD_DM_POLL('filler', 0, 50);
state := 1;

1: (* Connect all *)
FINS_CLIENT_CONNECT('mixer');
FINS_CLIENT_CONNECT('conveyor');
FINS_CLIENT_CONNECT('filler');
state := 10;

10: (* Running — read from each PLC *)
mixer_speed := FINS_CLIENT_READ_DM_WORD('mixer', 10);
conveyor_status := FINS_CLIENT_READ_DM_WORD('conveyor', 20);
fill_level := FINS_CLIENT_READ_DM_WORD('filler', 30);

(* Cross-PLC coordination: send mixer speed to filler *)
FINS_CLIENT_WRITE_DM_WORD('filler', 100, mixer_speed);
END_CASE;
END_PROGRAM

Source node sharing: When connecting to multiple PLCs, all connections use the same srcNode (ControlForge's node address). Each PLC identifies ControlForge by this source node. The destNode is different for each PLC.


6. Troubleshooting

SymptomCauseFix
Connect returns FALSEPLC not reachable on networkVerify IP with ping. Check that FINS/UDP is enabled on PLC. Confirm port 9600 is not firewalled.
Reads return all zerosWrong node addressesSet destNode to the last octet of the PLC's IP. Set srcNode to the last octet of ControlForge's IP.
Reads return all zerosAddress out of rangeVerify the DM/CIO addresses exist in the PLC program. CJ2M supports D0-D32767, CIO 0-6143.
Intermittent timeoutsNetwork congestion or poll rate too fastIncrease pollRateMs. Check for UDP packet loss with netstat -su.
Connection drops after PLC mode changePLC switched to PROGRAM modeSome PLCs reject FINS in PROGRAM mode. Switch PLC to RUN or MONITOR mode.
"Node address out of range" errordestNode or srcNode > 254Node addresses must be 1-254. Check PLC IP and FINS settings.
NX/NJ PLC does not respondFINS disabled on Sysmac controllerIn Sysmac Studio: Controller Setup > Built-in EtherNet/IP Port > FINS Settings > Enable FINS/UDP.
Writes succeed but PLC does not actWriting to wrong DM areaConfirm which DM addresses the PLC program reads for commands. Check CX-Programmer or Sysmac Studio.

Appendix A: Function Quick Reference

Client Functions (15)

FunctionReturnsDescription
FINS_CLIENT_CREATE(name, host [, port] [, destNode] [, srcNode] [, pollRateMs])BOOLCreate named connection to Omron PLC
FINS_CLIENT_CONNECT(name)BOOLOpen UDP connection and start polling
FINS_CLIENT_DISCONNECT(name)BOOLClose connection
FINS_CLIENT_IS_CONNECTED(name)BOOLCheck connection state
FINS_CLIENT_READ_DM(name, address, count)[]INTRead DM words (Data Memory)
FINS_CLIENT_WRITE_DM(name, address, values)BOOLWrite DM words
FINS_CLIENT_READ_DM_WORD(name, address)INTRead single DM word
FINS_CLIENT_WRITE_DM_WORD(name, address, value)BOOLWrite single DM word
FINS_CLIENT_READ_CIO(name, address, count)[]INTRead CIO words (Core I/O)
FINS_CLIENT_READ_CIO_WORD(name, address)INTRead single CIO word
FINS_CLIENT_ADD_POLL_ITEM(name, area, address, count)BOOLAdd generic memory area to poll list
FINS_CLIENT_ADD_DM_POLL(name, address, count)BOOLAdd DM range to poll list
FINS_CLIENT_ADD_CIO_POLL(name, address, count)BOOLAdd CIO range to poll list
FINS_CLIENT_DELETE(name)BOOLRemove client and all poll items
FINS_CLIENT_LIST()[]STRINGList all client instance names

Server Functions (8)

FunctionReturnsDescription
FINS_SERVER_CREATE(name, port [, node])BOOLCreate FINS UDP server (default node 0)
FINS_SERVER_START(name)BOOLStart listening on configured port
FINS_SERVER_STOP(name)BOOLStop server
FINS_SERVER_IS_RUNNING(name)BOOLCheck if server is listening
FINS_SERVER_SET_DM(name, address, value)BOOLSet DM word value
FINS_SERVER_GET_DM(name, address)INTRead DM word value
FINS_SERVER_DELETE(name)BOOLRemove server instance
FINS_SERVER_LIST()[]STRINGList all server instance names

7. FINS Server

ControlForge can also act as a FINS server — exposing DM memory words to Omron PLCs or other FINS clients. This enables ControlForge to act as a virtual I/O module or data bridge that Omron controllers can poll directly.

Server Lifecycle

PROGRAM POU_FINSServer
VAR
state : INT := 0;
ok : BOOL;
temperature : INT := 720; (* 72.0 degF x10 *)
pressure : INT := 450; (* 45.0 PSI x10 *)
cmd_from_plc : INT;
END_VAR

CASE state OF
0: (* Create server on FINS default port *)
ok := FINS_SERVER_CREATE('fins_srv', 9600);
IF ok THEN state := 1; END_IF;

1: (* Start listening *)
ok := FINS_SERVER_START('fins_srv');
IF ok THEN state := 10; END_IF;

10: (* Running — expose data to Omron PLCs *)
(* Omron PLC reads these via FINS Memory Area Read *)
FINS_SERVER_SET_DM('fins_srv', 0, temperature);
FINS_SERVER_SET_DM('fins_srv', 1, pressure);

(* Omron PLC writes commands via FINS Memory Area Write *)
cmd_from_plc := FINS_SERVER_GET_DM('fins_srv', 100);

IF NOT FINS_SERVER_IS_RUNNING('fins_srv') THEN
state := 1;
END_IF;
END_CASE;
END_PROGRAM

ControlForge v1.0.533 | FINS/UDP Client + Server | Omron CJ/NJ/NX Series | IEC 61131-3 Structured Text